MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector

MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector
MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector

Image Grand :  MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector

Détails sur le produit:
Lieu d'origine: Chine
Nom de marque: Huatec
Certification: ISO,CE
Numéro de modèle: HCDX-2000
Document: Movable magnetic particle f...00.pdf
Conditions de paiement et expédition:
Quantité de commande min: 1SET
Détails d'emballage: Dans la boîte en bois
Délai de livraison: 7~15 JOURS APRÈS PAIEMENT
Conditions de paiement: LC, T/T, Western Union
Capacité d'approvisionnement: 100 ensembles par mois

MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector

description de
Nom du produit: Détecteur de défauts de particules magnétiques Modèle: HCDX-2000
Méthode de magnétisation: L'équipement doit être équipé d'un dispositif de régulation de la fréquence de la chaleur. courant magnétisant: (CA): 0 2000A
Coil (facultatif): le diamètre intérieur φ 250 mm, le diamètre extérieur φ 380 mm Tension d'entrée: Pour les appareils à induction, le réglage de la tension doit être effectué à l'aide d'un système de
Mettre en évidence:

MPI flaw detector 0-2000A

,

movable magnetic particle flaw detector

,

magnetic particle testing equipment with warranty

MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector 


*HCDX-2000 movable type magnetic particle flaw detector can conduct AC or DC magnetization for parts. It also has automatic demagnetization function, without additional demagnetization device.

*The instrument has its own roller, which is flexible and light. It is applicable to aviation, machinery, automobile, railway, ship, pressure vessel and other manufacturing industries. It can detect the whole, part and abnormal parts of the parts, and also make the large-sized workpieces magnetized locally in sections.

*The instrument adopts 8-bit single chip microcomputer as the control core, and realizes continuous regulation of magnetization and demagnetization current through accurate acquisition of AC zero crossing signal and current regulating switch signal. It supports the function of limiting the maximum value of magnetizing current to prevent the current from mistakenly adjusting and ablating the workpiece. It has power off phase control function, and the remanence is stable. It is suitable for continuous method and remanence method flaw detection.

*During automatic demagnetization, the instrument automatically attenuates from the current magnetizing current value to zero; The instrument uses silicon controlled rectifier to adjust its conduction angle to control the magnetizing and demagnetizing current, so as to realize contactless adjustment of large current and prolong the service life of the instrument.

*The instrument is equipped with supporting rod copper rod, which can be used for flaw detection by supporting rod method; The output cables can also be connected with each other and wound on the shaft workpiece for winding method flaw detection. In addition, additional magnetizing coils or simple supports can be configured according to user requirements to form a simple bed flaw detector for small workpiece detection.


Main functions:

Flaw detection method: strut method (direct electrification method), winding method, coil method

Magnetization method: AC magnetization, DC magnetization (HWDC/FWDC)

Demagnetization method: AC demagnetization adopts remote demagnetization (attenuation method), and DC demagnetization adopts ultra-low frequency demagnetization


Technical parameters:

Magnetizing current (AC): 0 ~ 2000A (effective value), continuously adjustable, with power off phase control
(HWDC) 0-2000A (average)
Demagnetization (AC/HWDC) 2000 ~ 0A
Coil (optional) inner diameter φ 250mm, outer diameter φ 380mm
Temporary load rate 30%
Demagnetization time <5s
Input voltage 220V (single-phase)/380V (three-phase)
Frequency 50Hz/60Hz


Standard configuration:

Movable magnetic particle flaw detector host 1

Pole probe 1 set

Output cable 1 set

Standard test piece 1 set

Foot switch 1 set

Manual, certificate, packing list and warranty card 1 set


Optional configuration:

Magnetizing coil

Wound cable

Simple water tank for recovery and utilization of magnetic suspension

Magnetic suspension spray recovery system

Ultraviolet light

Fluorescent magnetic particle

Shading room

MPI Flaw Detector 0-2000A Movable Type Magnetic Particle Flaw Detector  0