HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization
HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

Image Grand :  HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

Détails sur le produit:
Lieu d'origine: Chine
Nom de marque: HUATEC
Certification: ISO,CE
Numéro de modèle: HCDX-1500
Conditions de paiement et expédition:
Quantité de commande min: 1 pièce
Détails d'emballage: en carton
Délai de livraison: 15-25 jours après le paiement
Conditions de paiement: T/T, Paypal, L/C, Western Union
Capacité d'approvisionnement: 100 ensembles par mois

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

description de
Courant alternatif: 0-1500A Alimentation: 220 V (système à trois fils biphasé) ± 10%, 50 Hz, courant instantané d'environ 100 A;
Méthode de magnétisation: L'équipement doit être équipé d'un dispositif de réglage de la fréquence d'écoulement de l'électrici Câble de sortie: 2 câbles souples à noyau de cuivre (120 mm2) de 3 mètres
Stabilité de la résistance: ≤±5% Nom du produit: Détecteur de défauts de particules magnétiques mobiles
Mettre en évidence:

HCDX-1500 magnetic particle flaw detector

,

mobile AC/HWDC flaw detector

,

movable flaw detector with demagnetization

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization  


The HCDX-1500 mobile magnetic particle flaw detector can magnetize parts in AC (or half wave DC magnetization HWDC). And with automatic demagnetization function, no additional demagnetization device is required.

8-bit MCU is adopted as the controller by this magnetic particles flaw detector, and the continuous regulation of magnetizing current can be realized through the precise collection of the AC zero voltage crossing signal and the signal of current regulation. It has the function of maximum current limit. With the function of phase controlled, the detector is suitable for both continuous technique and residual technique.


The current value is displayed on the analog ammeter or digital ammeter. The prod sets and trigger button are for operating in the narrow space.

The output current is reduced from the initial value to zero automatically when demagnetizing. Non-contact switch is adopted for the equipment.

This detector can be connected to the prod sets (handheld electrode sets) or spiral cable (flexible coil). Also there are some coils or electrodes designed for this equipment to become a simple inspection machine tool as option.


Technical parameters:

AC magnetization current

AC 0~1500A (effective value) continuously adjustable, short-time intermittent power, with power off phase control;

HWDC: 0~1500A (twice the average) continuously adjustable, short-time intermittent power;
Automatic demagnetizing current AC/HWDC 1500A~0 continuously adjustable, demagnetization time is shortened with the decrease of current
Output cable 2 copper-core flexible cables (120mm2) of 3 meters
Power supply 220V (two-phase three-wire system) ±10%, 50Hz, instantaneous current is about 100A
Dimensions 900(L)× 450(W)×950(h) mm; (not include the handle
Remanence stability ≤±5%
Temporary load rate ≤30%
Input voltage 380V 50Hz
Demagnetization time < 5s
Weight about 120kg


Main functions:

Detection methods: support rod method, winding method, coil method

Magnetization method: AC magnetization, DC magnetization (HWDC), pulse magnetization

Demagnetization method: AC demagnetization using far away method demagnetization (attenuation method), AC demagnetization using ultra-low frequency demagnetization


Standard configuration:

Mobile host 1pc

Support rod probe 1 set

robe cable 1pc

Foot switch 1pc

Optional accessories

Fixed coil

Wound cable

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization HCDX-1500 AC/HWDC Mobile/Movable Magnetic Particle Flaw Detector with Automatic Demagnetization

Coordonnées
HUATEC GROUP CORPORATION

Personne à contacter: Ms. Shifen Yuan

Téléphone: 8610 82921131,8618610328618

Télécopieur: 86-10-82916893

Envoyez votre demande directement à nous (0 / 3000)